A novel mass spectrometric ionization technique based on rapid evaporation of biological tissues (see picture) can be used to analyze vital tissues during surgical intervention as well as for processed tissue specimens. A tissue identification system based on principal-component analysis was developed. The method differentiates malignant tumor cells from the surrounding healthy tissue. Credit: (C) Wiley-VCH 2009

(麻豆淫院Org.com) -- Instead of the classic scalpel, surgeons can also operate with an electroscalpel. A significant advantage to this technique is that while a cut is being made, blood vessels are closed off and hemorrhaging eliminated. Now another advantage may be added as well: a German-Hungarian research team has developed a mass-spectrometry-based technique by which tissues can be analyzed during a surgical procedure.

As the team led by Zolt谩n Tak谩ts reports in the journal Angewandte Chemie, it may be possible to distinguish between malignant tumor cells and the surrounding healthy tissue in real time during cancer surgery. Until now, precise histological examination of the removed tissue has followed after tumor surgery, and has required several days. If it reveals that the tumor has not been completely removed, a second operation is needed. The new method may spare patients this second surgery in the future.

In electrosurgery, tissue is locally exposed to high-frequency electrical current in order to guide a cut, remove tissue, or halt bleeding. The tissue being treated becomes very hot and is partially vaporized. The electrical current also generates electrically charged molecules during the vaporization. The team of scientists from the University of Giessen, the Budapest firm Massprom, Semmelweis University, and the National Research Institute for Radiobiology and Radiohygiene, also in Budapest, made use of this process for their new method called rapid evaporation ionization , or REIMS. They equipped an electrosurgical instrument with a special pump that sucks the vaporized cell components up through a tube and introduces the charged molecules into a mass spectrometer.

It turns out that mainly lipids, the components of cell membranes, are registered by the mass spectrometer. 鈥淒ifferent tissue types demonstrate characteristic differences in their lipid composition,鈥 explains Tak谩ts. 鈥淭umor tissue also differs from healthy tissue.鈥 The scientists were able to develop a special algorithm to unambiguously identify and differentiate between types of tissue.

鈥淭issue analysis with REIMS, including data analysis, requires only fractions of a second,鈥 according to Tak谩ts. 鈥淒uring an operation, the surgeon thus received virtually real-time information about the nature of the tissue as he was cutting it.鈥 This opens new vistas for surgery in particular: the method helps to precisely localize the tumor during surgery and to delimit it from the surrounding healthy tissue. REIMS also provides information about whether the carcinoma is in an early or advanced stage.

More information: Zolt谩n Tak谩ts, In Vivo, In Situ Analysis Using Rapid Evaporative Ionization Mass Spectrometry, International Edition,