September 17, 2013

From graphite to water

Design of the graphite calorimeter for primary dosimetry in proton and ion beams.
× close
Design of the graphite calorimeter for primary dosimetry in proton and ion beams.

Scientists from the National Âé¶¹ÒùÔºical Laboratory (NPL), in collaboration with researchers in Belgium and Italy, have published research that could help provide a primary standard for dose measurements of carbon ion beam therapy used to treat cancer. The published paper was selected as a Featured Article in the journal Âé¶¹ÒùÔºics in Medicine and Biology.

While conventional radiotherapy uses or X-rays to destroy cancer cells, certain respond better to treatment using beams of charged ions. Ion beams can be focused on tumours with more precision, saving the surrounding healthy tissue, but currently only four carbon clinical facilities operate around the world: one in Germany, one in Italy and two in Japan.

One of the obstacles in the way of wider adoption of the therapy is the lack of a primary standard for measurements of the dose. As with any form of radiotherapy, or any type of medicine in general, the dose needs to be calculated accurately. If a patient receives too much, there could be side effects; if a patient receives too little, a few could survive and tumours could regrow.

The best way of calculating dose is to measure the heating effect caused by the absorption of radiation in a certain material, using a device called a ''. International protocols state that water should be used as the material, as it has similar absorption properties to the human body. An alternative is to use devices made from , rather than water. These have many advantages and NPL calorimeters are made from graphite. However, when using graphite calorimeters, a conversion factor needs to be applied so that the measurement results are given in terms of dose absorbed to water and conform to international protocols.

Get free science updates with Science X Daily and Weekly Newsletters — to customize your preferences!

This research carried out experiments and to determine this conversion factor for measurements made using a graphite calorimeter within a carbon ion beam. The final conversion depends on three properties: the depth at which measurements are made in the graphite; the water-to-graphite stopping power ratio, which explains how particles change speed as they ionise other atoms and molecules; and the fluence correction factor, which accounts for different nuclear interactions in water and graphite.

The lead author of the research, Séverine Rossomme, who worked at NPL and the Université catholique de Louvain, Belgium, on the project, said:

"Ion beam therapy is a promising treatment for a variety of cancers but without standards in place it will remain isolated to a few specialist treatment centres around the world and unavailable to a large number of patients. This research is contributing to the development of more reliable measurement standards, which will help make ion beam treatments more reliable and accessible to those that need them."

Read the full paper for free: